The Fluke 719 100G is a portable electric pressure calibrator designed for precise pressure measurements and calibrations up to 100 psi (7 bar)․ It features a built-in electric pump, user-friendly interface, and compatibility with various pressure modules, making it ideal for calibrating pressure transmitters and gauges in industrial settings․ The device comes with a range of accessories, including test leads, push-fit connectors, and a user manual on CD-ROM, ensuring convenience and accuracy in pressure calibration tasks․

1․1 Overview of the Fluke 719 Series

The Fluke 719 Series is a line of portable electric pressure calibrators designed for industrial applications․ These devices are engineered for precision and versatility, offering a range of pressure measurement and calibration capabilities․ The series includes models like the 30G and 100G, each tailored to specific pressure ranges; Known for their durability and user-friendly design, these calibrators are ideal for calibrating pressure transmitters, gauges, and other process instrumentation in the field or laboratory settings․

1․2 Key Features of the 100G Model

The Fluke 719 100G model stands out with its 100 psi (7 bar) pressure range and 0․01 psi resolution, ensuring high accuracy in measurements․ It features a built-in electric pump for easy pressure generation and a large LCD display for clear readings․ The device supports multiple pressure units, including psi, kPa, bar, and more, making it versatile for various applications․ Additionally, it comes with programmable pump limit settings to prevent over-pressurization, enhancing safety and operational efficiency․

Technical Specifications of the Fluke 719 100G

The Fluke 719 100G offers a pressure range of -12 to 120 psi, with 0․01 psi resolution and ±0․025% accuracy․ It supports multiple units like psi, kPa, and bar, ensuring versatility in various applications․ The device is powered by a rechargeable battery, providing extended operation in the field․ Its robust design and advanced sensor technology make it suitable for precise pressure calibration and measurement in industrial environments․

2․1 Pressure Range and Accuracy

The Fluke 719 100G offers a pressure range of -12 to 120 psi (7 bar) with a resolution of 0․01 psi, ensuring precise measurements․ Its accuracy is ±0․025% of full scale, meeting NIST-traceable standards․ The calibrator supports various pressure units, including psi, kPa, bar, and inH2O, making it versatile for diverse applications․ The electric pump allows for quick pressure generation and control, while programmable pump limits prevent over-pressurization, enhancing safety and operational efficiency in industrial calibration tasks․

2․2 Compatible Pressure Units

The Fluke 719 100G supports a wide range of pressure units, including psi, kPa, bar, mbar, inH2O, cmH2O, mmHg, and inHg․ This versatility allows users to perform calibrations across various measurement systems․ Pressure values are displayed with high resolution, ensuring accuracy and adaptability to different industrial applications․ The calibrator automatically adjusts to the selected unit, simplifying operations for technicians working with diverse pressure measurement requirements;

2․3 Electrical and Pump Specifications

The Fluke 719 100G features a built-in electric pump capable of generating pressures up to 100 psi (7 bar)․ It operates on (2) 9V alkaline batteries, ensuring portability and convenience․ The pump is designed for one-handed operation, allowing for efficient pressure generation and calibration․ Programmable pump limit settings help prevent over-pressurization, enhancing safety and control during calibration processes․ This design ensures reliable performance and ease of use in various industrial environments․

User Manual Highlights

The Fluke 719 100G user manual provides detailed instructions for operation, calibration, and maintenance․ It includes a quick start guide, menu navigation, and troubleshooting tips, available in 14 languages on CD-ROM for easy reference․

3․1 Quick Start Guide

The Quick Start Guide in the Fluke 719 100G manual helps users get started quickly․ It covers initial setup, connecting pressure modules, and basic operation steps․ The guide simplifies the process of configuring the device, performing calibrations, and understanding display readings․ Designed for ease of use, it ensures users can begin calibrating pressure devices efficiently, even without prior experience․ The guide is part of the comprehensive manual provided on CD-ROM․

3․2 Navigating the Menu System

The Fluke 719 100G features an intuitive menu system designed for easy navigation․ Users can access various functions, such as setting pressure limits, selecting units, and performing calibrations, using the dedicated buttons; The menu is logically organized to streamline operations, with clear options for configuration and measurement tasks․ Shortcuts are also available for frequently used functions, enhancing efficiency and user experience during calibration processes․

3․3 Calibration Procedures

The Fluke 719 100G allows for precise calibration of pressure devices using its built-in electric pump and programmable settings․ To calibrate, connect the device under test, select the appropriate pressure range, and use the menu to set target values․ The calibrator automatically generates and measures pressure, ensuring accuracy․ Refer to the user manual for step-by-step instructions and safety precautions․ The device also supports NIST-traceable calibration reports for documentation purposes․

Safety Information and Precautions

  • Always follow general safety guidelines to avoid hazards․
  • Wear protective gear when handling high-pressure systems․
  • Avoid over-pressurization, which can cause system damage․
  • Shut off valves and bleed pressure slowly before detachment․
  • ⚠️ Refer to the manual for detailed safety warnings․

4․1 General Safety Guidelines

Always follow safety guidelines to prevent hazards․ Use the calibrator as specified in the manual to avoid damage or injury․ Wear protective gear when handling high-pressure systems․ Ensure proper ventilation in the work area․ Avoid over-pressurization, which can lead to system damage․ Keep the device away from flammable materials․ Regularly inspect hoses and connections for wear․ Follow proper shutdown procedures to prevent sudden pressure releases․ Adhere to all warnings and cautions provided in the manual for safe operation․

4․2 Pressure Handling and Safety Warnings

Always handle pressure with care to avoid hazards․ Never exceed the maximum pressure rating of 100 psi (7 bar)․ Avoid sudden pressure releases, as they can cause injury or damage․ Use approved test hoses and ensure all connections are secure․ Shut off valves and bleed pressure slowly before disconnecting․ Prevent over-pressurization by using programmable pump limits․ Follow proper startup and shutdown procedures to maintain safety․ Refer to the manual for specific safety symbols and detailed pressure handling instructions․

Operating the Fluke 719 100G

The Fluke 719 100G is a portable, user-friendly pressure calibrator with a built-in electric pump, ideal for one-handed operation․ It provides precise pressure control and features a intuitive interface for easy navigation during measurements and calibrations․ The device is designed for versatility, supporting various pressure modules and test hoses, making it suitable for field and laboratory use․ Always follow the operating guidelines in the manual for optimal performance․

5․1 Initial Setup and Configuration

Begin by unpacking and inventorying all included accessories, such as TL75 test leads, push-fit connectors, and the translucent test hose․ Connect the pressure module to the sensor port, ensuring a secure fit․ Power on the device and follow the on-screen prompts to select units and configure basic settings․ Use the menu system to set pressure limits, mA output, and other parameters as needed․ Refer to the user manual for detailed instructions on initial setup and configuration to ensure optimal performance and accuracy in pressure calibration tasks;

5․2 Conducting Pressure Measurements

Connect the pressure module and test hose to the device under test․ Set the desired pressure range and units using the menu system․ Use the electric pump to generate pressure, monitoring the display for real-time measurements․ Once stable, record the readings․ For precise calibration, adjust the device under test to match the desired pressure, ensuring accuracy․ Always follow safety guidelines to avoid over-pressurization or system damage during the measurement process․

Calibration and Maintenance

Regular calibration ensures accuracy․ Use NIST-traceable reports for verification․ Replace batteries as needed․ Clean the device and store it in a protective holster to maintain performance․

6․1 Calibrator Maintenance Tips

Regular maintenance ensures optimal performance of the Fluke 719 100G․ Check and replace 9V alkaline batteries annually or when low-battery alerts occur․ Clean the exterior with a soft cloth and mild detergent, avoiding harsh chemicals․ Inspect and clean pressure connections to prevent contamination․ Store the calibrator in its protective holster when not in use to prevent damage․ Refer to the user manual for detailed maintenance procedures and ensure all repairs are performed by authorized Fluke service centers to maintain warranty validity․

6․2 Troubleshooting Common Issues

Common issues with the Fluke 719 100G include error messages, pressure module malfunctions, or pump failure․ If the display shows an error, restart the device or check connections․ Ensure pressure modules are securely plugged in and free from debris․ Low battery alerts indicate the need for replacement․ For persistent issues, consult the user manual or contact Fluke support․ Regular calibration and maintenance can prevent many problems, ensuring accurate and reliable performance in pressure calibration tasks․

Accessories and Additional Resources

The Fluke 719 100G includes TL75 test leads, AC72 alligator clips, push-fit connectors, and a user manual on CD-ROM․ Optional accessories and resources are available for enhanced functionality․

7․1 Included Accessories

The Fluke 719 100G comes with essential accessories to ensure optimal performance and convenience․ These include TL75 test leads, AC72 alligator clip set, push-fit connectors, and a translucent test hose․ Additionally, a protective yellow holster is provided for safe transport․ The device also includes a quick reference guide and a user manual on CD-ROM in 14 languages․ A NIST-traceable calibration report and data are provided, along with a 3-year warranty for added peace of mind․

7․2 Optional Accessories and Upgrades

Optional accessories for the Fluke 719 100G include additional pressure modules for expanded range capabilities and compatibility with various pressure types․ Users can also purchase spare battery packs and a rugged carrying case for enhanced portability․ Upgrades such as extended calibration intervals or advanced software tools are available to optimize performance․ These optional items allow users to tailor the calibrator to their specific needs, ensuring flexibility and longevity of the device in demanding industrial environments․

Leave a Reply